Today’s apparatus specifications seem to go on forever with many documents being over on hundred pages in length calling out every dashboard gauge, seat and interior trim color while referencing the NFPA 1901 Standard in numerous areas. While the old expression “The Devil is in the Details” still has merit, it is not surprising to work with apparatus committees who admit that they have not read the entire vehicle specification at any point in the design process. We probably can all recall attending some apparatus committee meeting where the focus seemed to be more on the color of warning light lenses and graphics design rather than on chassis and body components that could enhance safety and improve vehicle performance.
How we arrived at this stage is largely due to changes in the manufacturing and build process that are common in the industry. Did you ever notice that no two apparatus manufacturer’s specifications follow the same format when describing the vehicle components? Some may believe that this is done to discourage other folks from bidding, however the real reason is that many apparatus builders utilize their specifications to develop the bills of material and engineering required to successfully build the vehicle with all of the options requested by the department.
Virtually all apparatus builders utilize software programs to develop their specifications which start out a base models with options for virtually every component on the vehicle. If your department has not acquired a new unit within the past three to four years chances are that many of the specific model numbers and components have been upgraded and changed as technology moves forward. This is particularly noticeable with diesel engine and electronic components where federally mandated standards have influenced all types of automotive designs.
At some point in the specification development process the word format of the document can be distilled down to a component or stripper list which ranges from ten to fifteen pages in length that calls out each of the major components in single line fashion. This component list may then be used by some manufacturers for review at the pre-construction conference and final inspection as means to go over the entire vehicle. While this practice can save some time, this does not mean that the formal word specification should be forgotten, rather this is the document that the terms of the contract were stipulated and should be utilized throughout the build process for reference and to confirm that all areas of concern have been addressed.
Starting with the boiler plate portion of the specifications these first pages of the document are most important as they determine the “rules of the road” which should be developed with specific verbiage to favor the legal interests of the agency purchasing the vehicle. Areas which should be addressed include the requirements for bidders, engineering information, pre-construction conference and final inspection and certification testing, terms of acceptance and payment, delivery training and warranty requirements. Each of these areas and others are critical for the fire department to discuss and determine the process by which bids will be evaluated for compliance and where specific design criteria or overall dimensions are important. All of these areas need to be addressed up front before the committee debates the merits of single vs. two stage fire pumps or the size of the water tank.
For example, most manufacturers have developed base models of pumpers along with several body lengths and compartment dimensions. In order to have some degree of uniformity whatever the standard compartment depth or door height might be these numbers are called out in the specifications at times to two decimal points. While this works for that builder, not all manufactures may offer a compartment size to meet this specific requirement. For this reason the specification should include a listing of the critical dimensions including wheelbase, overall length, height, width, length of the cab, bumper extension, rear step, body length and hose bed height from the ground. Each of these areas should list a minimum and maximum permissible dimension to permit a prospective bidder to offer a vehicle design to meet these needs.
Cab design and components such as frontal and side air bags, seating design and seat belt hardware have been developed to enhance the safety environment for the driver, officer and crew. Cab seating layout in the past was somewhat limited by the length of the cab and where the apparatus manufacturer determined the location for the forward facing seats. With many departments operating with four to six personnel it does not make sense to specify the longest cab available which can add twelve to eighteen inches of wheelbase unless there are some specific requirements for interior EMS and tool storage.
Several apparatus manufacturers have designed their cab with multiple positions for forward facing seats which do not limit you to having two seats bolted to a seat riser within six inches of one another. Placement of seat belt retractors and belt assemblies have been designed to permit personnel to more easily don the seat belt with full PPE without having to adjust their position. Given the continued number of fire/rescue personnel that are injured each year on apparatus “Seated and Belted” should be the mantra of every fire department.
When starting out on any new vehicle it is important that the chief officers and stakeholders in the process determine the mission of the vehicle. This may seem simplistic, however there are many departments that due to the inability to determine the principle characteristics of the apparatus ended up with a unit that was too large, overweight and underutilized as few members wanted to get qualified to operate the rig.
Factors such as fire station bay space, first due response area roadways, terrain, bridges, state weight laws, tools and equipment carried all have a dramatic impact on how the vehicle should be designed and more importantly how it will perform over the next ten to fifteen years. The specification process should be a programmed and detailed process for everyone involved. Operational efficiency, safety and maintenance provisions should all be addressed as the apparatus committee works through the process.
Captions for photos: All images taken by Tom W. Shand
#1: This is the underside of a fabricated steel front bumper. Note the front and side supports to reinforce this area. This style of bumper will protect the crew and rig in the event of a frontal collision.
#2. Finish painted frame rails along with stainless steel straps and hardware on chassis components will resist rust and corrosion in these important areas that are often overlooked.
#3. Proper specification verbiage along with a close final inspection will reduce occurrences where excessive use of plastic wire ties are used to hold wire bundles in place.
#4. Chassis air reservoirs should be provided with remote cables that permit personnel to drain tanks on a regular basis.
#5. Body rub rails should be positioned and spaced out to protect all components including door hardware on roll up shutter doors.
#6. Consideration should be given to using switches on the officer’s side dash area to control warning devices to free up floor space.
#7. Plan out the interior cab space to accommodate map books, EMS equipment, chargers and radio equipment. Note that the rear of the engine tunnel is covered with aluminum tread plate in this high wear area.
#8. Step surfaces particularly at the rear tailboard should be provided with aggressive non-slip surfaces particularly in areas that experience snow and ice conditions to reduce slips and falls from the apparatus.
#9. Sliding hose bed covers permit personnel to operate these devices without having to climb on top of the engine prior to loading attack and supply line hoses. Always think safety when specifying stepping surfaces and points of access on the apparatus.
#10. Well-designed hose beds such as Engine 55 from the Freeland, Pennsylvania Fire Department are the result of detailed planning and specifications to determine the safe placement of handrails and stepping surfaces.
Tom W. Shand
April 4, 2015