TANKERS, TENDERS, MOBILE WATER SUPPLY APPARATUS GETTING IT RIGHT

Many years ago I had the privilege of working on the lesson plan for the New York State Water Supply program.  During that time I learned much about rural water supply in general and Tankers/Tenders in particular.  Some of what was learned was completely by accident. 

            The NFPA standard for Tankers / Tenders states that these apparatus must be capable of being filled at a rate of 1000 gallons per minute and must be able to be empty or dumped at the same rate of a 1000 gallons per minute minimum. How can you check your Tanker / Tender to make sure of this kind of performance?  Well it is pretty easy.  If you have a 3000 gallon per minute Tanker / Tender and a watch you just have to time it. If you can fill and dump the apparatus within 3 minutes or less than you have met the standard.

            But how do you know if all of the water is being emptied when you arrive at the dump site? The fact is that you do not unless you check it.  As we were piloting the State Water Supply Course we stumbled onto a very real problem.  We found Tankers / Tenders that were only capable of dumping 87%, 84% and yes we found one apparatus that was only dumping 71% of the water contained in the tank.  What does that mean in a practical application?  That if you had a 3000 gallon Tanker / Tender and it was only dumping 71% of the water that you no longer had a 3000 gallon Tanker / Tender but that the apparatus was only capable of delivering 2130 gallons of water and that you were constantly transporting the same 870 gallons of water over the road as it was never being dumped out.  There are many reasons that this might be occurring which include problems with the baffles or the sumps. Perhaps the tank design or an engineering mistake.

            How can you check to make sure that your 3000 gallon Tanker / Tender is actually dumping 3000 gallons of water.  First you must make sure that the apparatus tank is completely full. Next you must take the vehicle and get it weighed. Than dump all of the water that you can and weight the truck again.  With water weighing 8.34 pounds per gallon and if you have a 3000 gallon tank than the apparatus must weigh 25020 pounds less empty when you compare the full weight ticket to the empty weight ticket.

            As the Apparatus Architects have always said before you take delivery and pay for any new fire apparatus you must fill the vehicle up with all equipment and fluids and weigh the apparatus as outlined in NFPA 1911 Section 16.2.3.  If it is at all overweight than you cannot accept the vehicle until the manufacturer comes up with a remedy for the overweight condition if there is one.  If there is not one than you simply do not buy the vehicle.  With new Tankers / Tenders it is extremely important that the apparatus is delivered to you completely empty and with all the equipment and a full tank of fuel. You are now going to weigh the vehicle.  Than you are going to fill the water tank up and weight it again and then you are going to dump the water tank and weigh it again.  Two items you can now check off your delivery acceptance list.  That the vehicle is not over weight and that the vehicle is dumping the rated capacity of the tank.  As you are filling and dumping the tank it is advisable as part of the acceptance testing to time it to make sure that the Tanker / Tender can perform to the NFPA Standard of dumping and loading at a rate of at least 1000 gallons per minute.

            Many fire department are not doing any kind of acceptance testing upon delivery.  This is a big mistake.  The NFPA standards has acceptance requirements for all kinds of apparatus.  If you find that you have a 1500 gpm pump that upon delivery cannot deliver that required flow than you can send the unit back to the manufacturer and the unit can be fixed under warranty.  However if you wait until the first in service pump testing the unit maybe out of warranty and the fire department may have to pay for any repairs. The watch words here are to check and make sure you are getting what you paid for.